Product Name: 1000kW Natural Gas Generator Set
Generator Set model:1000GF-T
Rated Voltage: 400V/6.3kV/10.5kV
Â
Â
Genset 1000GF-T Specifications |
|
Engine model |
L12V200ZLT-2 |
Rated power |
1000KW/1250KVA |
Rated frequency |
50/60Hz |
Power factor |
0.8(Lag) |
Rated voltage |
400/6300/10500V |
Rated speed |
1000rpm |
Oil consumption |
≤1.0g/kWh |
Starting method |
Electrical starter DC24V |
Cooling method |
Closed water cooling |
Control method |
Electric control |
Connection method |
High elastic coupling |
Steady state voltage adjustment rate |
<±2.5% |
Voltage fluctuation rate |
±0.5% |
Transient voltage adjustment rate |
-15%~+20% |
Voltage stability time |
1.5s |
Steady state frequency regulation |
0~5%(adjusting) |
Frequency fluctuation rate |
0.50% |
Transient frequency adjustment rate |
±10% |
Frequency stability time |
7 s |
Dimension |
5800*1760*2800mm |
Weight |
18.5t |
Transient voltage regulation |
-15%~+20% UN |
Engine technical parameters |
|
Fuel |
Natural gas |
Type |
4-stroke, spark plug, turbocharge,inter cooling |
Cylinder No & Displacement |
12-cylinder,V type |
Bore*Stroke |
200mm×255mm |
Rated speed |
1000rpm |
Rated power |
1100kW |
Gas pressure |
1~4bar(100~400KPa) |
Heat consumption rate |
≤9000kJ/kWh |
Oil consumption rate |
≤1.0 g/kW·h |
Lubrication method |
Force and splash lubricating |
Alternator technical parameters |
|
Rated power |
1000kW/1250kVA |
Rated voltage |
400V |
Rated current |
1804A |
Rated frequency |
50Hz |
Power factor |
0.8(Lag) |
Rated speed |
1000rpm |
Wire connection method |
Y |
Insulation |
H |
Environment temperature |
0℃~40℃ |
Altitude |
≤1000m |
Protection |
IP23 |
Â

Â
In order to ensure the reliable and stable operation of the unit, there are requirements for the quality of natural gas and cooling water.
Natural gas should be dehydrated and must not contain water, crude oil and essential oil; natural gas pressure 100 ~ 400kPa; natural gas temperature -20 ~ 40℃.
◠Total sulfur content is less than 200mg/m3. The gas volume is the gas volume under standard conditions, that is, 100kPa atmospheric pressure, 20℃ ambient temperature, 30% relative humidity.
â— Cooling water requirements refer to the use of softened water in both high-temperature and low-temperature engine circulation systems. Cooling water should be weakly alkaline clean water, free of corrosive compounds such as chlorides, sulfates, acids, etc. Hardness: 0.7-5.3 mg/L, chloride ion content: <150 mg/L, pH value: 7-8.5.
â— We provide comprehensive services and formulate the most appropriate plans based on the unique needs of customers; we provide users with engineering drawings and commissioning training, regular after-sales service, and a 24-hour technical guidance hotline.